Measurement system analysis (MSA)

A measurement system analysis (MSA) is conducted at the start of the Measure phase to verify that the gage (measuring device) and the people using it can detect real process variation. If the measurement system is inadequate, all subsequent data — baseline, capability, and control charts — are unreliable. An adequate measurement system is normally confirmed before the Measure tollgate.

Why MSA matters

Observed variation in data comes from two sources:

If measurement system variation is large relative to part-to-part variation, you cannot distinguish real process changes from measurement noise.

Gage R&R components

ComponentDefinitionDetected by
Repeatability (EV)Variation when the same person measures the same part multiple times with the same gageEquipment variation: the gage itself
Reproducibility (AV)Variation when different people measure the same part with the same gageAppraiser variation: operator technique
Gage R&R (GRR)Total measurement variation = repeatability + reproducibilityCombined; the sum is not simply additive in linear terms
GRR² = Repeatability² + Reproducibility² (variances are additive) %GRR = (σ_GRR / σ_total) × 100%

Acceptance criteria

%GRR (of tolerance or total variation)Decision
<10%Measurement system is acceptable
10–30%Marginal; may be acceptable depending on the application and cost of improvement
>30%Unacceptable; measurement system needs improvement before proceeding

MSA study design (crossed Gage R&R)

The standard crossed Gage R&R study uses:

Other MSA properties

PropertyDefinitionHow to detect
Bias (accuracy)Difference between the average measured value and the true (reference) valueMeasure a reference standard; compare average to known value
LinearityConsistency of bias across the measurement rangeMeasure reference standards at multiple points; plot bias vs. reference value
StabilityConsistency of bias over timeMeasure a reference standard on a control chart; look for drift or shifts
ResolutionSmallest detectable increment; gage sensitivityGage resolution should be ≤1/10 of the spec width or process variation

Attribute agreement analysis

For attribute (pass/fail, go/no-go) measurement systems, use an attribute agreement analysis:

Common exam traps

Test yourself

The free 20-question CSSGB diagnostic covers all six Body of Knowledge sections, with an explanation for every answer.

Take the free CSSGB diagnostic

More: Data types · Basic statistics · Process capability · Control charts · Run charts